Picture Gallery
News Headlines

Mon. May 10th 2010
Installation of Officers

New officers of the Williamsville Fire Department were formally installed Saturday at the annual installation banquet. Shown ...

Read more »


Wed. May 5th 2010
Auto Extrication - Vehicle Roll Over

DRIVER TRAPPED — Williamsville firefighters worked for approximately 50 minutes to free the driver of a sport utility v...

Read more »


Fri. Jul 24th 2009
2008 Junior Firefighter of the Year

Chief Chris Petrie left, Junior Firefighter Christina Haffa and her Father Harry Haffa after her award presentation as 2008 J...

Read more »

Apparatus Gallery
Member Login

Username:


Password:




Links

NYS Dept. of Health


NFPA


Ellicott Creek




 Fire Glossary
 Print this page

Search:

Click a letter to view all entries that begin with that letter:
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

Page: | 1 | 2 | 3 |

S-130/S-190
The basic wildland fire training course given to all U.S. firefighters before they can work on the fire lines.


Safety zone
An area cleared of flammable material used for escape in the event the line is outflanked or in case a spot fire causes fuels outside the control line to render the line unsafe. In firing operations, crews progress so as to maintain a safety zone close at hand allowing the fuels inside the control line to be consumed before going ahead. Safety zones may also be constructed as integral parts of fuel breaks; they are greatly enlarged areas which can be used with relative safety by firefighters and their equipment in the event of blowup in the vicinity.


Salvage, salvage cover
Heavy-duty tarpaulins folded or rolled for quick deployment to cover personal property subjected to possible water or other damage during firefighting.


SAR
See Search and rescue.


Sawyer
Chainsaw crew, may also include faller" or "feller" who is qualified to cut down trees or snags perhaps while the tree or snag is burning.


SCBA
Self Contained Breathing Apparatus, or air-pack, worn by firefighters to protect against breathing toxic fumes and smoke, or where the air has insufficient oxygen. Often incorrectly called oxygen mask" by laypersons. Typically of open circuit style with a supply of compressed air where expired air is exhausted, rather than closed circuit where it is filtered, re-oxygenated from compressed oxygen, and inhaled again which is used where an air supply is needed for an extended period (up to four hours).


Scene safety
Steps taken at or near an emergency scene to reduce hazards and prevent further injuries to workers, victims or bystanders.


Scuttle hatch
Ready-made opening in roof that can be opened for vertical ventilation.


Search and rescue (or SAR)
Entering a fire building or collapse zone for an orderly search for victims and removal of live victims. Becomes recovery" if victims are not likely to be found alive.


Secondary line
Any fireline constructed at a distance from the fire perimeter concurrently with or after a line already constructed on or near to the perimeter of the fire. Generally constructed as an insurance measure in case the fire escapes control by the primary line.


Sector
A physical or operational division of an incident; an area supervised as a branch in the Incident Command System. A typical system for structure fires names the front" of the building "sector "A" and continues clockwise around the building (B, C, D) with interior sectors denoted by the floor number (1, 2, 3, etc.) . A "rehab" sector is one example of an operational division at an incident where personnel are assigned after strenuous work in another sector.


Self-contained breathing apparatus
See SCBA


Shoulder load
The amount of hose a single firefighter can pull off a hose wagon or pumper truck and carry toward the fire.


Shove knife
Semi-rigid metallic blade of various shapes and sizes used for forcing spring latches during forcible entry.


Siamese
Hose coupling for merging two streams into one, i.e., two female coupling inlets and one male coupling outlet.


Sides A, B, C, and D
Terms used by firefighters labeling the multiple sides of a building starting with side A or Alpha being the front of the structure and working its way around the outside of the structure in a clockwise direction. This labels the front side A or Alpha, the left side B or Bravo, the rear side C or Charlie, and the right side D or Delta.


Size-up
Initial evaluation of an incident, in particular a determination of immediate hazards to responders, other lives and property, and what additional resources may be needed. Example:Two-story brick taxpayer with heavy smoke showing from rear wooden porches and children reported trapped.


Skidder unit
Pre-configured tank, pump, hose for attachment to a logging skidder (large 4-wheel-drive tractor with a dozer blade, winch or grapple) to be carried to a fireline.


Slash
Debris resulting from such natural events as wind, fire, or snow breakage; or such human activities as road construction, logging, pruning, thinning, or brush cutting. It includes logs, chunks, bark, branches, stumps, and broken under-story trees or brush.


Slip-on
A small water pump and tank that can be temporarily mounted on a pickup or other truck.





Celebrating 150 Years


Current EMS Squad

Squad for September

  • 8/29-9/4      Squad 3
  • 9/5-9/11      Squad 4
  • 9/12-9/18    Squad 5
  • 9/19-9/25    Squad 1
  • 9/26-10/2    Squad 2 

Squad Hours - 12am-6am

 


Recent Calls

Wed. May 5th 2010
MVA - Maple & Hopkins - Roll Over

DRIVER TRAPPED - Williamsville firefighters worked for approximately 50 minutes to free the driver of a sport utility vehicle...

Read more »


Fri. Jun 26th 2009
Kitchen Fire at 250 Mill Street

Williamsville firefighters were alerted to a report of a possible kitchen fire at 250 Mill Street. Williamsville 9-2 called o...

Read more »


Sat. May 16th 2009
Bedroom Fire @ 34 Pasadena Place

Williamsville Firefighters responded to a bedroom fire early Saturday morning. 
Assist ant Chief Mike Measer arrived...

Read more »

Upcoming Events

Sat. Sep 11th 2010 4:00pm
Open House - Evening in the Village


Tue. Sep 14th 2010 7:00pm
CFR course


Thu. Sep 16th 2010 7:00pm
CFR course


Every 1st Mon. 7:00pm
Review Board Meeting


Every 2nd Tue. 7:30pm
Company meeting

Search Our Site

Search:



2010 Call Volume
  Fire EMS
January  15  43
February  20  24
March  20  34
April  13  27
May  13  36
June  10  44
July    
August    
September    
October    
November    
December    
Total 91208

View Call Volume History

Contact Information

Hutchinson Hose Co/Williamsville Fire Dept.
5565 Main St
Williamsville, NY  14221

Non-Emergency:
716-632-4070

Emergency:
911

Contact Us
Driving Directions
Map


YourFirstDue.com Managed web hosting for Fire/EMS



Login



Copyright © 2006-2010. YourFirstDue Inc.. All Rights Reserved. Designated trademarks and brands are the property of their respective owners. Content on this web site is supplied by Hutchinson Hose Co/Williamsville Fire Dept.. YourFirstDue Inc. cannot be held responsible or liable for any content, text, pictures, or any other media found on this web site. Maintained by the members and staff of Hutchinson Hose Co/Williamsville Fire Dept..

This site has been
viewed 141,083 times.